Guide for sellers and biomed teams

Wiping patient data from medical equipment before you sell it.

Imaging consoles, ultrasound systems and many networked devices keep patient data and hospital network credentials on board. This is what HHS requires, how NIST SP 800-88 sanitization works, and what to keep on file when the equipment leaves.

Short version. HHS allows reuse or disposal of electronic media only after the ePHI is removed by clearing, purging or destroying it, and points to NIST SP 800-88. Inventory every device with storage, ask the manufacturer where data lives, sanitize with a method that fits whether the device is being resold or scrapped, strip network settings, and keep a certificate listing each serial number and the method used.

Does HIPAA require removing patient data before selling medical equipment?

Yes. HHS says a covered entity may reuse or dispose of computers and other electronic media that store ePHI only after the ePHI has been removed or the media destroyed. The Security Rule requires policies for the final disposition of ePHI and the hardware it is stored on, and procedures for removing ePHI before media is reused (45 CFR 164.310(d)(2)(i) and (ii)). (HHS)

HHS’s disposal FAQ adds that workforce members who dispose of PHI must be trained on the entity’s disposal policies, and that a covered entity may hire a business associate to do the work under a contract that requires the vendor to safeguard PHI through disposal. (HHS disposal FAQ)

What do clear, purge and destroy mean under NIST SP 800-88?

HHS describes the three approaches this way: clearing overwrites media with non-sensitive data using software or hardware; purging means degaussing, exposing magnetic media to a strong magnetic field; and destruction means disintegrating, pulverizing, melting, incinerating or shredding the media. (HHS)

  • Clear. NIST describes logical techniques that apply standard read and write commands to overwrite user-addressable space. One pass is usually enough, and a manufacturer factory reset can be used if rewriting is not supported. (NIST SP 800-88r2 FAQ)
  • Purge. Includes degaussing for legacy magnetic media and cryptographic erase when its prerequisites are met.
  • Destroy. Disintegration, incineration, melting, pulverizing or shredding. NIST notes destruction gives the highest assurance level.

Revision 2 is current. NIST announced SP 800-88 Revision 2 on September 26, 2025, replacing the 2014 Revision 1. It shifts from media-by-media instructions to building a sanitization program, expands cryptographic erase guidance, and refers to IEEE 2883 and NSA specifications for device-specific techniques. (NIST bulletin, SP 800-88r2) It also adds a decision flow based on data sensitivity and whether media is reused inside or outside the organization. Selling equipment is reuse outside the organization, so use that branch.

Which medical devices store patient data?

Assume anything with a hard drive, SD card or USB storage holds something. ECRI notes that imaging devices generate PHI and may archive it until it is sent to clinical systems, that cardiac device programmers take data from patients, and that remote monitoring systems may be linked to a cloud service. (ECRI)

  • CT, MRI and other imaging consoles and workstations. Imaging equipment with hard drives holds PHI, and deleting the patient studies “does not insure that PHI is gone.” (Healthcare Innovation)
  • Ultrasound, including portable units. In 2016 Kaiser Permanente notified about 1,100 patients after stolen ultrasound units were found to hold data ranging from names and dates to medical record numbers and images. (Becker’s)
  • C-arms and fluoroscopy. Block Imaging tells sellers to remove all patient data before a sale and not to simply remove the hard drive. (Block Imaging)
  • Infusion pumps and other networked bedside devices. Rapid7 researchers bought 13 used infusion pumps on secondary markets such as eBay; 8 still held the original hospital’s Wi-Fi credentials. (Rapid7)
  • Lab and test instruments, and the PCs attached to them. Lab Manager lists imaging equipment, scanning devices and test equipment among devices that hold data, and recommends certificates of destruction for all devices by serial number. (Lab Manager)

For any model you are unsure about, check the manufacturer’s MDS2 form (Manufacturer Disclosure Statement for Medical Device Security), which ECRI says often contains the relevant security details, and ask the manufacturer where data is stored and which wipe utility it recommends.

Should you wipe or destroy the drive when the equipment is being resold?

It depends on whether the buyer needs the drive. ECRI says physically destroying the storage media is the strongest option if the device itself is being discarded, and that factory resets and built-in deletion features make recovery difficult but not impossible. (ECRI) For a system being resold, the drive usually carries the operating software the buyer is paying for, which is why Block Imaging tells C-arm sellers to use the manual’s deletion procedure or a service engineer rather than pulling the drive. If you do destroy a drive, tell the buyer in the listing so the software reload is priced in.

Beyond patient data, ECRI recommends removing network and interoperability settings (IP addresses, wireless settings, directory accounts, DICOM configuration) and disconnecting the device from any management server or cloud service, because a reactivated device could otherwise rejoin it.

What should a certificate of sanitization include?

NIST lists certificates of sanitization among the documentation a sanitization policy should require, and separates verification (checking that the technique finished without errors) from validation (the organization reviewing that evidence and formally approving the result). (NIST) At a minimum, keep:

  • Device make, model and serial number, and the serial number of each drive or storage module if available
  • Method used (clear, purge or destroy) and the tool or procedure, such as the OEM utility
  • Date, location, and who performed and verified the work
  • Written confirmation from any vendor that handled the media, which ECRI recommends, plus a business associate agreement where the vendor will see PHI

Record the decommissioning in your CMMS with the serial number and destruction method, as ECRI advises. Marketplaces expect it too: DOTmed’s seller terms require sellers to permanently remove patient data before transferring equipment. (DOTmed)

How much does data destruction for medical equipment cost?

Published pricing is for drives, not for imaging systems. One data destruction company gives these approximate ranges, which it says vary by provider, location and certification: (DataDestruction.com)

  • Software wiping: about $5 to $20 per drive
  • Degaussing: about $10 to $25 per drive
  • Shredding: about $10 to $40 per drive on site, or as low as $4 to $15 off site
  • On-site visit minimum: about $90 to $300 per visit, with on-site service adding a 50% to 100% premium over off-site
  • NAID AAA certified vendor: adds about 10% to 20%

We could not find published prices for an OEM or field engineer wipe of a CT, MRI or ultrasound console. Ask for a written quote that names the method and includes the certificate.

A data wipe checklist before equipment leaves the building

  1. Inventory every device with storage, including attached workstations, PCs, removable media and backup drives.
  2. Check the MDS2 and ask the manufacturer where data is stored and which wipe procedure it recommends.
  3. Export anything you must retain to your PACS or records system first.
  4. Sanitize with the method that fits: clear or purge for systems being resold with their drives, destroy for media that will not be reused.
  5. Remove network settings and disconnect from management or cloud services.
  6. Verify the result and get the certificate with serial numbers and method.
  7. File it in the CMMS and the sale file before release.

Selling imaging equipment? See how to sell a used MRI with escrow, the used C-arm selling checklist, or the hospital closure equipment timeline.

How TradePark handles this

Sellers can handle data removal themselves or add a certified NIST 800-88 data wipe as a paid service when listing with TradePark. Either way, the certificate goes in the deal file before removal. TradePark verifies the buyer, the buyer’s payment is held by a licensed escrow provider until inspection, and TradePark coordinates de-installation and freight.

List equipment, read how a deal works, or browse equipment for sale.

Questions

Does HIPAA require wiping medical equipment before it is sold?

Yes, for any device whose storage holds ePHI. HHS says a covered entity may reuse or dispose of electronic media only after the ePHI has been removed, by clearing (overwriting), purging (degaussing) or destroying the media, and it requires written policies for the final disposition of ePHI and the hardware it sits on (45 CFR 164.310(d)(2)(i) and (ii)).

What is the difference between clear, purge and destroy under NIST 800-88?

Clear uses standard read and write commands to overwrite user-addressable storage, usually in one pass. Purge uses stronger techniques such as degaussing magnetic media or cryptographic erase. Destroy physically disintegrates, incinerates, melts, pulverizes or shreds the media, and gives the highest assurance. NIST published Revision 2 of SP 800-88 in September 2025.

Is deleting patient studies from the console enough?

No. Deleting studies does not ensure the data is gone; the disk has to be overwritten or otherwise sanitized. Block Imaging also warns sellers not to simply pull the hard drive out of a C-arm, but to follow the manual’s deletion procedure or have a service engineer do it.

What should a certificate of sanitization include?

NIST lists certificates of sanitization as part of the documentation a sanitization program should keep. ECRI recommends recording the device serial number and the data destruction method used, and getting written confirmation from any third party that handles the media. Keep the certificate with the sale file.

How much does medical equipment data destruction cost?

For individual drives, one data destruction company lists software wiping at about $5 to $20 per drive and on-site shredding at about $10 to $40 per drive, with on-site minimums of about $90 to $300 per visit. Prices vary by provider and location. We could not find published pricing for OEM wipes of imaging consoles, so get a written quote.

Sources

Start here

Selling equipment that holds patient data?

Send the make, model and quantity. We reply within one business day with a value range and a plan for the data wipe, removal and payment through escrow.